Home / Stability checks
Retaining wall stability check
Generate a cantilever or gravity wall from its dimensions, add a shear key or a heel or toe projection, and check it against the IBC 1807.2.3 combinations or a full set of operation, construction, flood and 100/30 seismic cases.
Loads the app includes
- Self weight and the soil resting on the heel (virtual back through the heel, or pressure on the actual faces)
- Hill-side backfill with Rankine, Coulomb, at-rest or your own K, sloping ground with an optional rise limit, and surcharge
- Hill-side and riverside water tables, with uplift taken from the level of each point of the base
- Riverside backfill: none, active, at rest, or passive used only as far as needed to balance the base pressure
- Passive resistance on shear keys, acting only against the direction of movement
- Pseudo-static earthquake with the Mononobe-Okabe dynamic increment, including the surcharge
Checks
- Sliding, overturning and base eccentricity
- Allowable bearing pressure (no tension beyond the kern)
- Ultimate bearing capacity on B − 2e (Vesic)
- Flotation
- Search for the minimum key depth or base projection that passes
Worked example
The default section is a 6 m cantilever wall on a 5.0 m base with a 1.4 m toe, backfilled to the top with 10 kPa surcharge, checked for the three IBC 1807.2.3 combinations. These are the app's own results for that section; open the app to see every combination, the forces and the figure.
| Check | Worst value | Limit | Governing combination | |
|---|---|---|---|---|
| Sliding | 1.15 | ≥ 1.1 | W3 Static + seismic | OK |
| Overturning | 2.08 | ≥ 1.1 | W3 Static + seismic | OK |
| Max. bearing pressure (kPa) | 106 | ≤ 200 | W2 Static, river empty (drawdown), hill-side water table | OK |
| Bearing capacity | 2.21 | ≥ 2 | W3 Static + seismic | OK |
3 of 3 combinations pass.
Other structure types
Gravity dam and weir stability check, Hill-side canal stability check, Settling basin stability check, Box culvert stability check