Generate a cantilever or gravity wall from its dimensions, add a shear key or a heel or toe projection, and check it against the IBC 1807.2.3 combinations or a full set of operation, construction, flood and 100/30 seismic cases.

Open the retaining wall check

Loads the app includes

Checks

Worked example

The default section is a 6 m cantilever wall on a 5.0 m base with a 1.4 m toe, backfilled to the top with 10 kPa surcharge, checked for the three IBC 1807.2.3 combinations. These are the app's own results for that section; open the app to see every combination, the forces and the figure.

CheckWorst valueLimitGoverning combination
Sliding1.15≥ 1.1W3 Static + seismicOK
Overturning2.08≥ 1.1W3 Static + seismicOK
Max. bearing pressure (kPa)106 ≤ 200W2 Static, river empty (drawdown), hill-side water tableOK
Bearing capacity2.21≥ 2W3 Static + seismicOK

3 of 3 combinations pass.