Home / Stability checks
Box culvert stability check
Generate a single or multi-cell box culvert with haunches and base projections, put uniform fill over it or different ground levels on each side, and check it with the cells full or empty.
Loads the app includes
- Self weight, earth fill on the top slab and walls (at rest or active), and the fill over base projections
- Live load on the top slab and live load surcharge on the walls
- Groundwater on both sides and uplift
- Water and sediment inside the cells that are full in each combination
- Earthquake on the body, the fill and the water inside
Checks
- Bearing pressure and ultimate bearing capacity
- Sliding and base eccentricity
- Flotation with the box empty and groundwater high
- IRC SP:13 style cases, or every full / empty cell pattern
Worked example
The default section is a 3 × 3 m single-cell box culvert under 2 m of fill, with groundwater at 1.2 m and 20 kPa live load, checked for five culvert combinations. These are the app's own results for that section; open the app to see every combination, the forces and the figure.
| Check | Worst value | Limit | Governing combination | |
|---|---|---|---|---|
| Sliding | 1.98 | ≥ 1.25 | B5 Box empty + earthquake towards riverside (20% live load) | OK |
| Max. bearing pressure (kPa) | 173 | ≤ 188 | B5 Box empty + earthquake towards riverside (20% live load) | OK |
| Bearing capacity | 14.05 | ≥ 2 | B5 Box empty + earthquake towards riverside (20% live load) | OK |
| Flotation | 5.88 | ≥ 1.2 | B2 Box empty, groundwater, surcharge on hill-side (left) wall only | OK |
5 of 5 combinations pass.
Other structure types
Gravity dam and weir stability check, Retaining wall stability check, Hill-side canal stability check, Settling basin stability check