Home / Stability checks

Gravity dam and weir stability check

Draw a concrete or masonry gravity section, or generate it from height, crest width and slopes, and check it for every load combination of IS 6512:1984 or USACE EM 1110-2-2100. Galleries are cut out of the section as voids.

Open the gravity dam check

Loads the app includes

Checks

Worked example

The default section is a 22 m concrete gravity dam with a 5 m crest, a 0.9 H : 1 V downstream slope and a 2 × 2.5 m drainage gallery, checked for the seven IS 6512 load combinations (construction, normal operation, flood, earthquake, and drains inoperative). These are the app's own results for that section; open the app to see every combination, the forces and the figure.

CheckWorst valueLimitGoverning combination
Sliding1.03≥ 1E B + earthquake, no iceOK
Max. base pressure (kPa)566 ≤ 1500A Construction, emptyOK
Flotation2.09≥ 1.1G E, drains inoperativeOK

7 of 7 combinations pass.

Other structure types

Retaining wall stability check, Hill-side canal stability check, Settling basin stability check, Box culvert stability check