The section updates as soon as you change the type or any dimension, and replaces the current vertices (Undo brings them back). Convention: x runs from the upstream or backfill side (heel) to the downstream side (toe); y is elevation.
Drag points on the drawing to move them. Any order works; the app orients the polygon itself. Heel and toe are found automatically or you can pick them.
One void per line as x,y pairs separated by spaces, e.g. 1.5,2 3.5,2 3.5,4.5 1.5,4.5
One x,y per line (comma, tab or space). Works with coordinates copied from Excel or AutoCAD LIST output cleaned to two columns.
Save the section from AutoCAD as DXF (ASCII). Closed LWPOLYLINE, POLYLINE and chains of LINE entities are read; arc bulges are split into short segments. The largest closed loop becomes the outer boundary and loops inside it can become voids.
Works on any section, generated or imported. The hill side or backfill side is the heel. Turn on passive resistance on the cutoff in tab 2 (Foundation) so a key adds sliding resistance. Soil resting on a heel projection is picked up automatically from the backfill inputs.
Load combinations pick these from a list. The upstream or hill-side level also acts as the water table in the hill-side backfill. Leave blank if not used.
Sediment deposited inside adds weight (and seismic inertia) to the structure. It helps against sliding and flotation but raises the base pressure and, in a single full chamber, the eccentricity. With "use only when critical", each combination is checked with and without the sediment and the worse result is kept; the results show which was used.
Only faces of 45° or steeper count. Riverside faces resist movement towards the river, with depth from the top of the riverside backfill (or the toe level); hill-side faces resist movement towards the hill, with depth from the heel level. The force used never exceeds what the other loads need. The sliding FS option also applies to riverside backfill set to passive.
With different levels, the ground over the top slab is taken as a straight line from the left ground level to the right one. On the left wall the slope is allowed for through K: Rankine Ka for the slope when active is chosen, and K0·(1 + sin β) when at rest is chosen. The Mononobe-Okabe increment acts on the left (higher) side.
The fill weight σ'v = γ·depth acts on the top slab and on any base projections, and K·σ'v acts on both outer walls; below the groundwater level the submerged weight is used and the water is added separately. Live load on the top slab is the pressure from the design vehicle (for example IRC Class 70R or Class A) spread through the fill depth; work it out for your fill and enter it here. Live load surcharge on a wall is K·γ·h_eq over its full height.
The ground surface starts at the given level where it meets the structure and rises at β towards the hill, up to the rise limit if one is set. With the virtual back, the thrust Pa = ½·K·γ·H'² acts on a vertical plane through the heel, where H' runs from the base up to the sloping ground above the heel, so it can be taller than the structure. It is inclined at β (Rankine) or δ (Coulomb). All soil above the structure on the hill side, including the sloping wedge, is counted as weight. With actual faces, K·σ'v acts on each face with σ'v taken from the ground directly above that point. Water below the upstream level is added separately as pore pressure.
For each combination the app finds the passive percentage that brings the resultant to the centre of the base (heel pressure = toe pressure), from that combination's own active and other loads. If the maximum permissible passive would give more reaction than needed, only the balancing amount is used. If even the maximum cannot balance the base, the maximum is used and the toe pressure stays higher. With the extra tick box, the passive force is also never more than the net driving horizontal force. Combinations with movement towards the hill keep their own hill-side passive factor. The percentage used is shown in the results and the report.
Full water pressure still acts through the silt. The IS 6512 button converts the combined equivalent fluids into the silt-only part: γ'v = (19.25 − 9.81)·g/9.81 and Ks·γ' = (13.6 − 9.81)·g/9.81.
Body inertia acts at the centroid of the concrete. Direction is set per combination by the sign of the factor: EQH +1 pushes downstream, −1 pushes upstream (empty reservoir case). Hydrodynamic pressure acts on the upstream face below the upstream level.
Point loads per metre run: live load on the deck, gate or hoist reactions, wave force, machine dynamic loads, anchors and so on. Loads with the same group name share one factor column in the combination table.
Water levels: pick a named level or "Custom level" from each list. Factors multiply each load group (use −1 to reverse a seismic direction). Criteria: leave a field at 0 or blank to skip that check. Heel tension accepts kPa or a multiple of fck such as 0.01fc.
Builds a full set of combinations using the chamber or cell count from the geometry. Chamber or cell 1 is next to the hill (left). Every combination gets a readable name, so the search box above can pick out any group.
Governing check is the check closest to (or furthest past) its limit, as a utilisation: 100% is exactly at the limit, above 100% fails. N is the net vertical force (down positive, after uplift). H is the net horizontal force (downstream positive). e is measured from the base centre, positive towards the toe. q heel is the linear (uncracked) stress at the heel, negative means tension. Tap a row for details.
Projects are kept in this browser on this device only. To move a project to another computer or keep a backup, use "Save project file (.json)" below.
The report has a cover page with the issue table, contents, design basis (codes, units, sign convention, criteria, method), geometry, parameters, loads, load combinations with a load factor matrix, results with the envelope and a utilisation chart, detailed calculations with the formula used for each check, conclusions with options for any failing check, and an approval block. The HTML report opens in any browser and prints to A4.
Copied JSON can be pasted back below to restore a project. Your latest inputs are also kept in this browser.